Review




Structured Review

AliveCor Inc kardia monitor device series
(A) Venn diagram depicting the primary mechanism of arrhythmia detection for select commercially available devices. Estimated retail price included. (B) Images of selective devices. <t>(i)</t> <t>AliveCor</t> <t>Kardia</t> Monitor device series . This device utilizes a single-lead ECG strip that can be mounted onto the back of a phone case or external card. Patients place one finger from each hand on to the two electrodes on the strip, and the devices records a single-lead ECG tracing. These devices have integrated algorithms that are able to detect the presence of AF based on the irregularity of the RR intervals and presence of a P-wave. Picture source: https://store.alivecor.com/products/kardiamobile , (ii) AliveCor KardiaMobile 6L . This device produces a six-lead ECG tracing by using a sensor on the back of the device that can be placed on the leg. It may be well suited for patients with atrial flutter, where flutter waves are better visualized in lead II. Picture source: https://store.alivecor.com/products/kardiamobile6l , (iii) Apple Watch. This series of wearable devices has been well studied for the detection of AF. Earlier iterations of the watch relied solely on PPG to detect heart rhythm irregularities, however the Series 4 and more recent iterations provide blended PPG and ECG capabilities. Picture source: https://www.apple.com/healthcare/apple-watch/ , (iv) Fitbit Sense . This wearable device uses PPG technology to detect heart rhythm abnormalities; there are additional apps available to provide ECG tracings. In this picture, we see that the Fitbit Sense describes the heart rhythm as AF, normal sinus or inconclusive. Picture source: https://www.fitbit.com/global/us/technology/ecg , (v) Samsung Galaxy Watch . This series of wearable devices can detect irregular heart rhythms with blended PPG and ECG technology. Here, we see multiple screens showing the device’s prompt for the user to participate in an ECG measurement, a live tracing and an interpreted rhythm as sinus, respectively. Picture source: https://www.cnet.com/how-to/samsung-adds-ecg-monitor-to-galaxy-watch-3-and-galaxy-watch-active-2/
Kardia Monitor Device Series, supplied by AliveCor Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/kardia+monitor+device+series/kardia+ecg+monitor/pmc08288067-49-11-10
Average 90 stars, based on 1 article reviews
kardia monitor device series - by Bioz Stars, 2026-08
90/100 stars

Images

1) Product Images from "Mobile Health for Arrhythmia Diagnosis and Management"

Article Title: Mobile Health for Arrhythmia Diagnosis and Management

Journal: Journal of General Internal Medicine

doi: 10.1007/s11606-021-07007-w

(A) Venn diagram depicting the primary mechanism of arrhythmia detection for select commercially available devices. Estimated retail price included. (B) Images of selective devices. (i) AliveCor Kardia Monitor device series . This device utilizes a single-lead ECG strip that can be mounted onto the back of a phone case or external card. Patients place one finger from each hand on to the two electrodes on the strip, and the devices records a single-lead ECG tracing. These devices have integrated algorithms that are able to detect the presence of AF based on the irregularity of the RR intervals and presence of a P-wave. Picture source: https://store.alivecor.com/products/kardiamobile , (ii) AliveCor KardiaMobile 6L . This device produces a six-lead ECG tracing by using a sensor on the back of the device that can be placed on the leg. It may be well suited for patients with atrial flutter, where flutter waves are better visualized in lead II. Picture source: https://store.alivecor.com/products/kardiamobile6l , (iii) Apple Watch. This series of wearable devices has been well studied for the detection of AF. Earlier iterations of the watch relied solely on PPG to detect heart rhythm irregularities, however the Series 4 and more recent iterations provide blended PPG and ECG capabilities. Picture source: https://www.apple.com/healthcare/apple-watch/ , (iv) Fitbit Sense . This wearable device uses PPG technology to detect heart rhythm abnormalities; there are additional apps available to provide ECG tracings. In this picture, we see that the Fitbit Sense describes the heart rhythm as AF, normal sinus or inconclusive. Picture source: https://www.fitbit.com/global/us/technology/ecg , (v) Samsung Galaxy Watch . This series of wearable devices can detect irregular heart rhythms with blended PPG and ECG technology. Here, we see multiple screens showing the device’s prompt for the user to participate in an ECG measurement, a live tracing and an interpreted rhythm as sinus, respectively. Picture source: https://www.cnet.com/how-to/samsung-adds-ecg-monitor-to-galaxy-watch-3-and-galaxy-watch-active-2/
Figure Legend Snippet: (A) Venn diagram depicting the primary mechanism of arrhythmia detection for select commercially available devices. Estimated retail price included. (B) Images of selective devices. (i) AliveCor Kardia Monitor device series . This device utilizes a single-lead ECG strip that can be mounted onto the back of a phone case or external card. Patients place one finger from each hand on to the two electrodes on the strip, and the devices records a single-lead ECG tracing. These devices have integrated algorithms that are able to detect the presence of AF based on the irregularity of the RR intervals and presence of a P-wave. Picture source: https://store.alivecor.com/products/kardiamobile , (ii) AliveCor KardiaMobile 6L . This device produces a six-lead ECG tracing by using a sensor on the back of the device that can be placed on the leg. It may be well suited for patients with atrial flutter, where flutter waves are better visualized in lead II. Picture source: https://store.alivecor.com/products/kardiamobile6l , (iii) Apple Watch. This series of wearable devices has been well studied for the detection of AF. Earlier iterations of the watch relied solely on PPG to detect heart rhythm irregularities, however the Series 4 and more recent iterations provide blended PPG and ECG capabilities. Picture source: https://www.apple.com/healthcare/apple-watch/ , (iv) Fitbit Sense . This wearable device uses PPG technology to detect heart rhythm abnormalities; there are additional apps available to provide ECG tracings. In this picture, we see that the Fitbit Sense describes the heart rhythm as AF, normal sinus or inconclusive. Picture source: https://www.fitbit.com/global/us/technology/ecg , (v) Samsung Galaxy Watch . This series of wearable devices can detect irregular heart rhythms with blended PPG and ECG technology. Here, we see multiple screens showing the device’s prompt for the user to participate in an ECG measurement, a live tracing and an interpreted rhythm as sinus, respectively. Picture source: https://www.cnet.com/how-to/samsung-adds-ecg-monitor-to-galaxy-watch-3-and-galaxy-watch-active-2/

Techniques Used: Stripping Membranes

Validation Studies for Selected Ambulatory Rhythm Monitoring Technologies for Atrial Fibrillation
Figure Legend Snippet: Validation Studies for Selected Ambulatory Rhythm Monitoring Technologies for Atrial Fibrillation

Techniques Used: Biomarker Discovery



Similar Products

90
AliveCor Inc kardia monitor device series
(A) Venn diagram depicting the primary mechanism of arrhythmia detection for select commercially available devices. Estimated retail price included. (B) Images of selective devices. <t>(i)</t> <t>AliveCor</t> <t>Kardia</t> Monitor device series . This device utilizes a single-lead ECG strip that can be mounted onto the back of a phone case or external card. Patients place one finger from each hand on to the two electrodes on the strip, and the devices records a single-lead ECG tracing. These devices have integrated algorithms that are able to detect the presence of AF based on the irregularity of the RR intervals and presence of a P-wave. Picture source: https://store.alivecor.com/products/kardiamobile , (ii) AliveCor KardiaMobile 6L . This device produces a six-lead ECG tracing by using a sensor on the back of the device that can be placed on the leg. It may be well suited for patients with atrial flutter, where flutter waves are better visualized in lead II. Picture source: https://store.alivecor.com/products/kardiamobile6l , (iii) Apple Watch. This series of wearable devices has been well studied for the detection of AF. Earlier iterations of the watch relied solely on PPG to detect heart rhythm irregularities, however the Series 4 and more recent iterations provide blended PPG and ECG capabilities. Picture source: https://www.apple.com/healthcare/apple-watch/ , (iv) Fitbit Sense . This wearable device uses PPG technology to detect heart rhythm abnormalities; there are additional apps available to provide ECG tracings. In this picture, we see that the Fitbit Sense describes the heart rhythm as AF, normal sinus or inconclusive. Picture source: https://www.fitbit.com/global/us/technology/ecg , (v) Samsung Galaxy Watch . This series of wearable devices can detect irregular heart rhythms with blended PPG and ECG technology. Here, we see multiple screens showing the device’s prompt for the user to participate in an ECG measurement, a live tracing and an interpreted rhythm as sinus, respectively. Picture source: https://www.cnet.com/how-to/samsung-adds-ecg-monitor-to-galaxy-watch-3-and-galaxy-watch-active-2/
Kardia Monitor Device Series, supplied by AliveCor Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/kardia+monitor+device+series/kardia+ecg+monitor/pmc08288067-49-11-10
Average 90 stars, based on 1 article reviews
kardia monitor device series - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

Image Search Results


(A) Venn diagram depicting the primary mechanism of arrhythmia detection for select commercially available devices. Estimated retail price included. (B) Images of selective devices. (i) AliveCor Kardia Monitor device series . This device utilizes a single-lead ECG strip that can be mounted onto the back of a phone case or external card. Patients place one finger from each hand on to the two electrodes on the strip, and the devices records a single-lead ECG tracing. These devices have integrated algorithms that are able to detect the presence of AF based on the irregularity of the RR intervals and presence of a P-wave. Picture source: https://store.alivecor.com/products/kardiamobile , (ii) AliveCor KardiaMobile 6L . This device produces a six-lead ECG tracing by using a sensor on the back of the device that can be placed on the leg. It may be well suited for patients with atrial flutter, where flutter waves are better visualized in lead II. Picture source: https://store.alivecor.com/products/kardiamobile6l , (iii) Apple Watch. This series of wearable devices has been well studied for the detection of AF. Earlier iterations of the watch relied solely on PPG to detect heart rhythm irregularities, however the Series 4 and more recent iterations provide blended PPG and ECG capabilities. Picture source: https://www.apple.com/healthcare/apple-watch/ , (iv) Fitbit Sense . This wearable device uses PPG technology to detect heart rhythm abnormalities; there are additional apps available to provide ECG tracings. In this picture, we see that the Fitbit Sense describes the heart rhythm as AF, normal sinus or inconclusive. Picture source: https://www.fitbit.com/global/us/technology/ecg , (v) Samsung Galaxy Watch . This series of wearable devices can detect irregular heart rhythms with blended PPG and ECG technology. Here, we see multiple screens showing the device’s prompt for the user to participate in an ECG measurement, a live tracing and an interpreted rhythm as sinus, respectively. Picture source: https://www.cnet.com/how-to/samsung-adds-ecg-monitor-to-galaxy-watch-3-and-galaxy-watch-active-2/

Journal: Journal of General Internal Medicine

Article Title: Mobile Health for Arrhythmia Diagnosis and Management

doi: 10.1007/s11606-021-07007-w

Figure Lengend Snippet: (A) Venn diagram depicting the primary mechanism of arrhythmia detection for select commercially available devices. Estimated retail price included. (B) Images of selective devices. (i) AliveCor Kardia Monitor device series . This device utilizes a single-lead ECG strip that can be mounted onto the back of a phone case or external card. Patients place one finger from each hand on to the two electrodes on the strip, and the devices records a single-lead ECG tracing. These devices have integrated algorithms that are able to detect the presence of AF based on the irregularity of the RR intervals and presence of a P-wave. Picture source: https://store.alivecor.com/products/kardiamobile , (ii) AliveCor KardiaMobile 6L . This device produces a six-lead ECG tracing by using a sensor on the back of the device that can be placed on the leg. It may be well suited for patients with atrial flutter, where flutter waves are better visualized in lead II. Picture source: https://store.alivecor.com/products/kardiamobile6l , (iii) Apple Watch. This series of wearable devices has been well studied for the detection of AF. Earlier iterations of the watch relied solely on PPG to detect heart rhythm irregularities, however the Series 4 and more recent iterations provide blended PPG and ECG capabilities. Picture source: https://www.apple.com/healthcare/apple-watch/ , (iv) Fitbit Sense . This wearable device uses PPG technology to detect heart rhythm abnormalities; there are additional apps available to provide ECG tracings. In this picture, we see that the Fitbit Sense describes the heart rhythm as AF, normal sinus or inconclusive. Picture source: https://www.fitbit.com/global/us/technology/ecg , (v) Samsung Galaxy Watch . This series of wearable devices can detect irregular heart rhythms with blended PPG and ECG technology. Here, we see multiple screens showing the device’s prompt for the user to participate in an ECG measurement, a live tracing and an interpreted rhythm as sinus, respectively. Picture source: https://www.cnet.com/how-to/samsung-adds-ecg-monitor-to-galaxy-watch-3-and-galaxy-watch-active-2/

Article Snippet: Estimated retail price included. (B) Images of selective devices. (i) AliveCor Kardia Monitor device series .

Techniques: Stripping Membranes

Validation Studies for Selected Ambulatory Rhythm Monitoring Technologies for Atrial Fibrillation

Journal: Journal of General Internal Medicine

Article Title: Mobile Health for Arrhythmia Diagnosis and Management

doi: 10.1007/s11606-021-07007-w

Figure Lengend Snippet: Validation Studies for Selected Ambulatory Rhythm Monitoring Technologies for Atrial Fibrillation

Article Snippet: Estimated retail price included. (B) Images of selective devices. (i) AliveCor Kardia Monitor device series .

Techniques: Biomarker Discovery